Marine Cable Sizing and Voltage Drop for Lithium Systems


Understand marine DC cable sizing for lithium batteries, inverters, alternators, solar and high-current loads.

Cable size is determined by more than current.

Consider:

  1. continuous current
  2. peak current
  3. run length
  4. acceptable voltage drop
  5. ambient temperature
  6. bundling
  7. termination
  8. conductor insulation rating
  9. circuit protection
  10. marine environmental exposure

Why 12V systems are demanding

A 3,000W inverter can require around 260A from a 12.8V bank at high output.

A relatively small resistance at 260A creates substantial voltage drop and heat.

Voltage-drop concept

Voltage drop = Current x resistance

For a two-conductor DC circuit, consider the complete current path, not only the positive cable length.

Connections count

A large cable with a poor crimp can still fail.

Inspect lug quality, correct crimp tooling, lug-to-stud fit, torque, strain relief, cable support, heat-shrink, corrosion protection and bend radius.


Practical context

Make the installation verifiable

A credible marine installation should be inspectable, documented and recoverable after a protection event. The battery label alone cannot show whether fault current, isolation, charging control, mounting and essential services have been addressed.

  1. Document cable sizes, protection ratings, isolation points, charging settings and BMS warning or shutdown logic.
  2. Confirm that terminals are protected, equipment is restrained and the location is suitable for heat, water and service access.
  3. Have the completed system commissioned and retain the drawings, settings, test results and equipment manuals aboard.

Work out your own numbers